ISO 286 Fits and Tolerances
ISO 286 is the international system of limits and fits that gives each hole and shaft a tolerance class such as H7/g6, where the letter sets the zone position, and the number sets its width. Ø25 H7/h6 allows 0 to 34 µm of clearance while H7/p6 gives 1 to 35 µm of interference.
A fit in mechanical joining and assemblies defines the relationship between mating parts (hole and shaft), whether they leave a gap, transition, or overlap. ISO 286 defines standard fits and tolerance classes for Holes and shafts of varying nominal sizes. Their designations are labelled in design and provide consistent information for designers, engineers, vendors, manufacturers, quality inspectors, and other stakeholders.
Whether you are a designer trying to figure out which fit class you should use or a procurement officer ordering parts with strict quality control of mechanical fits, understanding the ISO fit concept and interference fit tolerance chart is essential to achieve desired results.
This guide explains how the code is built, which fits you will really use, the numbers behind them, IT grades & processability, and thermal effects on fit tolerances.
What a Fit Is: Hole, Shaft, and the Tolerance Zone
Fit is a mechanical feature that defines how two mating surfaces behave, such as a lock, grip, slide, or locate. Hole and shaft are the two mating features in the fit. A hole is an internal feature, such as a bore & shaft width, whereas a shaft is an external feature, like a pin or a key.
A tolerance zone is used to characterize the fit between a hole and a shaft, defining the permissible deviation (the upper and lower limits of their sizes). International tolerance grades (IT grades) define the allowable range between the upper and lower size limits. Consequently, locations are determined based on H, g, k, p, and other symbols.
Tolerance Zone Example for Ø25 H7/g6
The callout of “Ø25 H7/g6” indicates that the basic size (nominal size) of the hole/shaft is 25 mm. H defines the fundamental deviation for the hole, whereas “7” denotes the total width of the tolerance zone (value obtained from the IT grade table). Similarly, in g6, g is the fundamental deviation for the shaft, and “6” denotes the IT grade that provides the variation limit for the shaft (value obtained from the IT grade table).

Tolerance Zone Example
From the IT grade table for Ø25 nominal size, we get the following values for fundamental deviations of holes and shafts.
- IT6 grade tolerance =13 µm
- The fundamental deviation for shaft position (g, upper deviation) = −7 µm
- Lower deviation = Upper deviation -IT6 tolerance= -7-13= -20 µm
- Maximum Deviation = 21-(-20) = 41-20 µm
- Keeping the hole size standard ( Ø 25 mm)
- Maximum permissible shaft size= Nominal size + upper deviation= 25-0.007= 24.993 mm
- Minimum permissible shaft size= Nominal size + lower deviation= 25.000-0.020= 24.980 mm
The result shows the permissible shaft size is 24.993 to 24.980 mm with clearance fit.
Try Prolean Now!
How ISO 286 Is Built?
ISO 286 is an international standard for defining the limits and fits (linear) for cylindrical features and two opposite surfaces. It provides uniformity in design, manufacturing, inspection, and repair. The ISO 286 standards include “letters” and “numbers” for fundamental deviations and the width of the tolerance zone. Based on ISO 286 codes, you can distinguish the clearance, transition, and interference fits.
For example, H7/g6 ;
H→ Hole Position
7→ Hole IT Grade
g→ Shaft Position
6→ Shaft IT Grade
IT Grades Set the Zone Width
IT (International Tolerance) grades define the width of a dimensional tolerance zone based on the nominal size of a part. They are part of the ISO 286 system of limits and fits and are identified by numerical values following the tolerance-position letters in a fit designation. For example, in H7, H represents the fundamental deviation (tolerance position), and 7 represents the IT tolerance grade.
There are 20 standard IT grades, ranging from IT01, IT0, IT1, IT2, IT3, through IT18. As the IT grade number increases, the tolerance zone becomes wider, allowing greater dimensional variation. For successive grades from IT5 onward, the tolerance width increases by approximately 60%.
The Letter Sets the Zone Position (Fundamental Deviation)
Letter symbols are used to set the position of the tolerance zone with respect to the nominal size. Capital Letters (A to ZC) are used for hole positions and small letters (a to ZC) for the shaft positions.
|
Fit Group |
Hole |
Shaft |
Position of Tolerance Zone |
|
Large clearance |
A to C |
a to c |
Distant from nominal |
|
Running clearance |
D to G |
d to g |
Slightly clear of nominal |
|
Zero reference |
H |
h |
Touches nominal |
|
Transition |
JS, J, K, M, N |
js, j, k, m, n |
Straddles or sits near the nominal |
|
Interference |
P to ZC |
p to zc |
Above nominal shaft |
Why are H and h both “Zero at Nominal”?

Nominal size in ISO fit
Both H and h are zero at the nominal (basic size) because it provides the maximum material limit, so ISO 286 has been systematically designed to pair an H hole with an h shaft, always excluding the interference fit. For the H hole, the lower limit is equal to zero, and the zone moves upward from the nominal size, whereas the upper limit of the h shaft is zero, and the zone moves downward.
You can set H or h constant (Hole or shaft basis) and change only one of their sizes to set the desired fit.
Let’s take an example of an Ø20 H7/h6 fit, which means the minimum clearance is 0 and the maximum clearance is the sum of the two tolerance widths (21 + 13 = 34 µm). The inspector can easily check whether a locating fit is tight enough by comparing the result with the maximum allowable tolerance width of 34 µm.
H7/h6 Chart: Common Preferred Fits at Ø25 mm

H7/h6 chart
The ISO hole-basis system uses an H-position hole as the reference, while the shaft tolerance position and IT grade determine the resulting clearance.
The following H7/h6 chart compares five commonly preferred clearance fits at a nominal diameter of Ø25 mm [4].
|
Fit |
Minimum clearance (µm) |
Maximum clearance (µm) |
Fit description |
|
H11/c11 |
110 |
370 |
Loose running fit |
|
H9/d9 |
65 |
169 |
Free running fit |
|
H8/f7 |
20 |
74 |
Close running fit |
|
H7/g6 |
7 |
41 |
Sliding fit |
|
H7/h6 |
0 |
34 |
Locational clearance fit |
Hole-Basis Fits You Will Actually Use?
Hole-based fits are more common in design and manufacturing because keeping hole sizes fixed at nominal values simplifies tooling and fit verification. Since the tools for hole-making are available in fixed sizes, you can fix the hole size and machine the shafts by turning and grinding to adjust the dimensions within the tolerance limit.
H7/g6 Sliding
H7/g6 is a clearance fit with close sliding of the shaft, and provides a small space for the lubricant film. Some common applications of H7/g6 fit are slide bushings, guide pins, and spool valves.
H7/h6 Locational
H7/h6 is a clearance fit (down to zero clearance) and is used to locate parts & slide them by hand with lubrication. Spigots, pilots, change parts, and gears with keys are a few examples of applications.
H7/k6 Transition
H7/k6 is a transition fit, which means it can be a small interference or clearance, depending on the actual sizes of the hole and shafts. The mating parts are assembled using either the slip or press-fit method. The difference between slip fit vs press fit is that you use Press Fit when there is a small interference, and slip fit when there is a small clearance.
H7/p6 Light Press
In H7/p6, the shaft size is larger than the H7 hole, forming an interference fit. They are used for firm location and retention through contact pressure between mating surfaces. The joints can transmit axial loads and are useful in bearing ring assemblies, locating dowels, and other similar applications.
H7/s6 Drive
As the shaft tolerance class moves from p6 to s6, the interference increases. The H7/s6 provides a drive fit for permanent assemblies. The higher contact pressure between mating surfaces improves torque transmission and resistance to movement. However, it increases the assembly force and stress.
H7/u6 Force
Based on nominal size and material type, H7/u6 needs a high-pressure or sink assembly. It creates tight and relatively permanent joints. The joints can resist relative rotation and axial movement, such as in heavy-duty couplings and gear rims.
Clearance and Interference Values at Ø10 / 25 / 50 / 100 mm
For a 25 mm nominal size, H7/h6 gives 0 to 34 µm clearance and H7/p6 gives 1 to 35 µm interference. Moreover, the values of clearance and interference for the same tolerance/fit class vary with nominal size.
The clearance and interference fit tolerance chart below outlines the clearance and interference values for Ø10 / 25 / 50 / 100 mm under different tolerance classes, from loose clearance fits to heavy interference fits.
|
Nominal diameter ( Ø, mm) |
Fit class |
Fit type |
Minimum clearance (µm) |
Maximum clearance (µm) |
|
10 |
H7/g6 |
Clearance |
5 |
29 |
|
10 |
H7/h6 |
Clearance |
0 |
24 |
|
10 |
H7/k6 |
Transition |
−10 |
14 |
|
10 |
H7/n6 |
Transition |
−19 |
5 |
|
10 |
H7/p6 |
Interference |
−24 |
0 (press fit) |
|
10 |
H7/s6 |
Interference |
−32 |
−8 |
|
10 |
H7/u6 |
Heavy interference |
−37 |
−13 |
|
25 |
H7/g6 |
Clearance |
7 |
41 |
|
25 |
H7/h6 |
Clearance |
0 |
34 |
|
25 |
H7/k6 |
Transition |
−15 |
19 |
|
25 |
H7/n6 |
Transition |
−28 |
6 |
|
25 |
H7/p6 |
Interference |
−35 |
−1 |
|
25 |
H7/s6 |
Interference |
−48 |
−14 |
|
25 |
H7/u6 |
Heavy interference |
−61 |
−27 |
|
50 |
H7/g6 |
Clearance |
9 |
50 |
|
50 |
H7/h6 |
Clearance |
0 |
41 |
|
50 |
H7/k6 |
Transition |
−18 |
23 |
|
50 |
H7/n6 |
Transition |
−33 |
8 |
|
50 |
H7/p6 |
Interference |
−42 |
−1 |
|
50 |
H7/s6 |
Interference |
−59 |
−18 |
|
50 |
H7/u6 |
Heavy interference |
−86 |
−45 |
|
100 |
H7/g6 |
Clearance |
12 |
69 |
|
100 |
H7/h6 |
Clearance |
0 |
57 |
|
100 |
H7/k6 |
Transition |
−25 |
32 |
|
100 |
H7/n6 |
Transition |
−45 |
12 |
|
100 |
H7/p6 |
Interference |
−59 |
−2 |
|
100 |
H7/s6 |
Interference |
−93 |
−36 |
|
100 |
H7/u6 |
Heavy interference |
−146 |
−89 |
Try Prolean Now!
Shaft-Basis Fits: When the Shaft Comes First?
Shaft-basis fits mean the shaft size is fixed at the nominal value, whereas the hole position changes to set the fit. This is less common in engineering because the hole-making tools come in fixed sizes, and it is relatively challenging to change the hole dimensions.
In some applications, shaft-basis fits are a better choice than hole-basis fits, especially when your shaft size is already fixed for the desired assembly—for example, standardized shaft stock, parts with multiple fits on one component, and vendor-supplied parts.
In ISO 286, G7/h6 matches H7/g6, K7/h6 matches H7/k6, P7/h6 matches H7/p6, and so on.
Selection Rules of Thumb
The selection of fit type and tolerance classes depends on the desired functionality, manufacturing capabilities, stress conditions, and choice of hole-basis system.
Let’s look at the seven rules of thumb for selecting fit and tolerance.
- The first rule of thumb is “choose hole-basis fits as default, unless shaft-basis is absolutely necessary for assembly”.
- Make the hole one grade coarser than the mating shaft for IT tolerance grades up to IT7.
- Higher IT grades increase surface roughness; lower grades are suitable for a smooth finish.
- Choose the IT tolerance grade that is the loosest among those that work for your assembly. It can save machining and quality-verification costs.
- At maximum interference, ensure the hole wall stays below yield, whereas confirm the joint can withstand the load at minimum interference.
- Use clearance fit when mating parts must move, slide, or rotate. Choose H7/g6 for close-running and H9/d9 for loose-fit.
- For locating parts, choose h6 or k6. If you need to transmit load without a key or fastener, choose p, s, or u after calculation.
Can Your Process Hold It? IT Grade to Process Table

Hole boring process
The IT tolerance grade process table allows manufacturers to choose and ensure that the manufacturing process can meet the required tolerances. It guides which processes are suitable for achieving different IT tolerance grades with proper tooling and process control.
You can refer to the given table for a first screen to confirm with your own process capability data (Cpk).
|
IT grades |
Process Capability |
|
IT3 to IT5 |
Lapping, superfinishing |
|
IT4 to IT6 |
Honing |
|
IT5 to IT7 |
Cylindrical / precision grinding |
|
IT5 to IT7 |
Diamond / fine boring |
|
IT5 to IT7 |
Wire EDM |
|
IT6 to IT8 |
Reaming |
|
IT6 to IT8 |
Broaching |
|
IT6 to IT9 |
CNC turning (finish pass) |
|
IT7 to IT10 |
CNC milling (finish pass) |
|
IT10 to IT13 |
Drilling |
|
IT10 to IT12 |
Investment casting |
|
IT11 to IT13 |
Die casting |
|
IT9 to IT13 |
Injection molding |
|
IT11 to IT13 |
Metal powder-bed AM (as built) |
|
IT11 to IT14 |
SLA / SLS polymer AM |
|
IT13 to IT16 |
FDM |
|
IT13 to IT16 |
Sand casting |
[5]
Temperature: When a Good Fit Binds?
Each metal/alloy expands or shrinks at a different rate as the temperature changes, so you need to consider the temperatures of assembly, fitting, and functional operations, especially when working with two or more types of metals and alloys. Only after that, the fit does not loosen or tighten from the intended position, and it ensures a good fit.
For instance, the size of a shaft at 20 °K is different from that at -40 °K. The change in size can be calculated through the given formula;
ΔD = α × D × ΔT ( α is the coefficient of thermal expansion, D is the feature size at room temperature, and ΔT is the change in temperature)
Example: The Changes in Size of a Steel shaft ( Ø25 g6) and Aluminum Housing (Ø25 H7) at −40 K.
ΔT = -40-20= −60 K
Difference is Contraction = (23 − 11.5) × 10⁻⁶ × 25 × 60 ≈ 17 µm
Since the ISO minimum clearance is only 7 µm, the fit goes to roughly 10 µm of interference, and the parts bind. Here, the intended fit varies with thermal variation. Therefore, you must calculate the change in size of each part at each extreme with ΔD = α × D × ΔT. Then, compare the resulting fit with the minimum and maximum limits from the ISO table. Accordingly, you can change the fit class or the materials if it falls outside the safe range.
Try Prolean Now!
Clearance vs. Interference Fit

Clearance vs. interference fits
More precisely, ISO defines a fit as the relationship between an external feature of size and an internal feature of size (typically a shaft and a hole) intended for assembly. used to control the assembly requirements. There are three types of fits: clearance, transition, and interference. A clearance fit has a gap between the shaft and the hole, whereas an interference fit has no gap & the shaft size is larger than the hole.
The table below shows the key differences between clearance vs interference fit;
|
Parameter |
Clearance fit |
Interference fit |
|
Relationship |
Hole > shaft |
Shaft > hole |
|
Relative movement |
Possible |
Typically, no movement |
|
Assembly |
Free to light force |
It requires pressing and controlled assembly |
|
Main design purpose |
Movement, rotation, and easy assembly |
Retention, torque transmission, etc. |
|
Potential risk |
Looseness and movement |
Excessive assembly stress |
|
Example |
H7/g6 |
H7/p6 |
ISO 286-2 provides the numerical tables of standard tolerance classes and limit deviations for holes and shafts, whether your assembly needs clearance, transition, or interference fits.
Hole basis vs shaft basis systems for fits
The hole-basis system uses a basic hole with zero fundamental deviation, and different shaft tolerance classes are selected to obtain the required fit. In contrast, the shaft-basis system uses a basic shaft with zero fundamental deviation, while different hole tolerance classes are selected to achieve the required fit.
Let’s look at a sample of an interference fit tolerance chart, which includes press fit tolerance for different nominal sizes. You can use these tables to determine whether a particular hole/shaft combination produces the desired clearance, transition, or interference fit.
Are you interested in other types of fits beyond the cylindrical fits of holes and shafts? Read Snap Fit Type and Aluminum Extrusion Tolerances & Standards here.

A sample of an interference fit tolerance chart
Inch Equivalents: ANSI B4.1 RC / LC / LT / LN / FN
ISO 286 provides standard values and specifications in the metric system, so you need to refer to other standards equivalent to ISO for fit and tolerance specifications in inches. You can use ANSI B4.1, which provides preferred limits and fits for cylindrical parts.
IN ANSI B4.1, the fit classes are Running or Sliding Clearance Fits (RC), Locational Clearance Fits (LC), Locational Transition Fits (LT), Locational Interference Fits (LN), and Force and Shrink Fits (FN).
|
ANSI family |
Fit Description |
Corresponding ISO fit (Approx.) |
|
RC 1–2 |
Close / sliding running |
H6/g5 to H7/g6 |
|
RC 3–4 |
Precise close running |
H7/f6 to H8/f7 |
|
RC 5–6 |
Medium running |
H8/e7 |
|
RC 7–9 |
Free/loose running |
H9/d9 to H11/c11 |
|
LC 1–3 |
Locational clearance (tight) |
H6/h5 to H8/h7 |
|
LC 4–6 |
Locational clearance (medium) |
H10/h9, H7/g6, H9/f8 |
|
LC 7–11 |
Locational clearance (loose) |
H10/e9 to H13/c11 |
|
LT 1–2 |
Locational transition (close) |
H7/js6 |
|
LT 3–4 |
Locational transition (medium) |
H7/k6 |
|
LT 5–6 |
Locational transition (tight) |
H7/n6 |
|
LN 1–3 |
Locational interference |
H6/n5, H7/p6, H7/r6 |
|
FN 1–5 |
Force and shrink fits (light to heavy) |
H7/s6 to H7/u6 and heavier |
Need Parts Complying with Specific ISO 286 Fits and Tolerances?
If you need mechanical parts that need to comply with specific fit and tolerance classes as labelled in your design, ProleanTech can help you. We have equipment and machinery that execute several processes to achieve the desired IT grades.
In our machine shop, the multi-axis CNC machining facility that can provide dimensional tolerances as low as ±0.005mm (0.0002″). Meanwhile, our engineer uses CMMs, digital gauges, micrometres, and other instruments to inspect and verify the desired fit.
Mentioning the required fit class and tolerances in engineering drawings makes it easier for the manufacturer to estimate costs and produce parts accordingly. So, if you want to know how much it costs to produce components complying with Specific ISO 286 fits and tolerances, upload your design and get a quote within 24 hours.
FAQs
What is the difference between clearance and interference fits?
The main difference between clearance and interference fits is that the hole is larger than the shaft throughout their specified dimensional limits. In contrast, it is smaller than the shaft in interference fits. Interference fits overlap the shaft & holes, whereas a clearance fit allows relative movement between them.
Why is H7/h6 a common fit choice?
H7/h6 is a common ISO 286 fit choice because it can be used for accurate location with small clearance, particularly when components need to be assembled and disassembled without a press fit. You can choose H7/h6 for components requiring easier sliding or rotation.
Can ISO fits be converted to inches?
No, tolerance zones under ISO fits are metric-based, and you cannot directly convert them to inches while retaining the same designation. However, you can use ASME B4.1 for inch-based tolerance zones and fits.
Does the nominal size change the tolerance?
Yes, the nominal size changes the tolerances even for the same grade, and tolerance increases with the nominal size. For instance, an H7 hole of 10 mm has a 15 µm zone (10.000 to 10.015 mm), while a 100 mm H7 hole has a 35 µm zone (100.000 to 100.035 mm).