Get a Quote →

APPLICATION / MEDICAL

Medical equipment

Medical equipment parts.
Device housings and precision components with traceable materials.

Housings, instrument components and fixtures for medical equipment. We work to your material specification and drawing, with material traceability and the inspection records your project requires.

SPECIFICATION

TYPICAL PARTS
Device housings, instrument components, assembly fixtures
PRIMARY ROUTE
CNC milling, CNC turning, Swiss turning
COMMON MATERIALS
Stainless steel 304 and 316L, aluminium, titanium, PEEK
A machined component used to illustrate medical equipment applications
Medical equipment

APPLICATION REQUIREMENTS

What decides the design here.

Four things shape the route before a tool is selected. If any of them is unknown at enquiry, we say so instead of assuming a default.

Read the design guide
04.1

Intended use and contact conditions

Whether the component contacts the patient, a fluid path, or only the equipment structure. This drives material choice and surface requirements.

04.2

Cleaning and surface quality

Cleaning method, acceptable surface roughness and edge break. Crevices and burrs are usually the first thing a cleaning validation finds.

04.3

Material traceability

Grade, certificate source and whether the certificate has to accompany the parts.

04.4

Documentation scope

Which records your project needs: material certificate, dimensional report or a defined inspection sheet.

PARTS WE MAKE

Parts for this application,
and the geometry that shapes them.

Workshop photographs of real geometry. Each one carries the route, what the machine has to reach, what is checked, and what you need to state on the drawing.

See more part geometry
Manufactured housing with bores and mounting faces

Device housing

Bores, sealing faces and the wall sections around them, plus how the housing closes. Crevices at the joint are what a cleaning validation finds first.

ROUTECNC millingCHECKEDMating fit and sealing face
STATE ON THE DRAWING

Specify the mating fit, the sealing face finish and any cosmetic surfaces.

Turn-mill part with intersecting bores and machined mounting faces

Instrument component with intersecting bores

Concentricity between intersecting bores and the mounting faces, and the burr condition at the intersection. A burr inside a bore is not a cosmetic defect.

ROUTETurn-millCHECKEDBore concentricity and burr condition
STATE ON THE DRAWING

Call out the bore sizes, the datum face and the deburring requirement.

A bead-blasted machined part with a uniform matt surface

Uniform matt-finish component

A bead-blasted surface is uniform and hides tool marks, but it also rounds edges and holds residue if the roughness is not specified. Cleaning method and roughness go together.

ROUTECNC milling + bead blastingCHECKEDRoughness and edge condition
STATE ON THE DRAWING

State the roughness call-out, the cleaning method and which edges must stay sharp.

PROCESSES, MATERIALS AND FINISHES

The routes used for these parts.

Not every route suits every part. These are the ones that come up most for this application; the quote states the route chosen for your geometry and quantity.

All capabilities

Finishing changes dimensions: coating thickness, masking and any effect on a mating fit are agreed before the route is fixed, not discovered at inspection.

INSPECTION AND DOCUMENTATION

What we measure, and what we record.

The inspection scope is agreed with the order. Anything you need recorded has to be stated before machining starts, because it cannot be reconstructed afterwards.

Tolerancing standards
Coordinate measuring machine probe in the Prolean inspection area

Dimensional inspection

Datums, bore sizes and mounting patterns measured against your drawing, with the method agreed before production.

A surface roughness tester beside a calibration block

Surface roughness

Roughness measured where the drawing calls it out, on sealing, sliding and contact faces.

Our handheld alloy analyser in its protective case

Material verification

Alloy grade checked before machining. Certificate scope is agreed with the material order, not added afterwards.

Where a programme requires verification we cannot give in-house, independent third-party testing or inspection can be arranged. The scope and the cost are agreed in the quote, not added later.

AGREED BEFORE THE ORDER STARTS

  • 01Drawing revision and the intended use of the component
  • 02Material grade, specification and certificate source
  • 03Surface roughness call-outs on contact and cleaning faces
  • 04Edge-break and deburring requirements
  • 05Dimensional report scope and inspection method
  • 06Cleaning, handling and packing instructions

APPROVED CASE STUDIES

Case studies for this application.

A case study needs approved objective, process, inspection and result records. We do not publish a project until that approval exists.

STATUS

Case studies are being prepared for publication.

The part photographs above are workshop images of real geometry. They show what can be made, not a completed project: material, tolerance, quantity and delivery results are published only where the customer has approved the record. Until then, the fastest way to see whether your part fits our route is an engineering review.

QUESTIONS

Medical questions.

The questions that come up for this application. Anything not covered here goes to an engineer.

Are you ISO 13485 certified?

No. We hold ISO 9001:2015 through SGS. We can supply material certificates, dimensional reports and the inspection records you specify; we do not manufacture under an ISO 13485 quality system. Where your project needs independent verification, third-party testing can be arranged and the scope agreed in the quote.

Can you supply implantable or sterile components?

No. Our scope is equipment hardware and non-implantable components. Anything entering a sterile or implantable pathway is outside what we take on.

Can you provide material certificates?

Yes where the material is supplied with certification. State the certificate type when you request the quote so it can be sourced with the material.

What surface finish is realistic on a cleaning face?

It depends on the material and the geometry. Give the roughness call-out and the cleaning method, and we confirm what the route can hold before quoting.

How is the lead time set?

From geometry, material sourcing and inspection scope. Certificate and documentation requirements are part of that, so they need to be stated at enquiry.

START WITH YOUR DRAWING

Bring your next part
to an engineering review.

Send CAD or a drawing, quantity, material and critical requirements. We will review the manufacturing route, price and lead time.